{"id":933,"date":"2021-09-30T22:28:55","date_gmt":"2021-09-30T20:28:55","guid":{"rendered":"http:\/\/hentati.org\/?p=933"},"modified":"2021-12-27T18:00:58","modified_gmt":"2021-12-27T17:00:58","slug":"create-uplink-profile-transport-node-profile-configure-host-transport-node","status":"publish","type":"post","link":"https:\/\/hentati.org\/index.php\/2021\/09\/30\/create-uplink-profile-transport-node-profile-configure-host-transport-node\/","title":{"rendered":"Step4: Create Uplink Profile, Transport Node Profile &#038; Configure Host Transport Node"},"content":{"rendered":"<p><span style=\"color: #000000;\"><strong>Link for all Steps :<\/strong> <a href=\"http:\/\/hentati.org\/index.php\/2021\/12\/10\/10-steps-to-deploy-nsx-t\/\">10 Steps to Deploy NSX-T<\/a><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>(Previous Step) Step 3 : <\/strong><a href=\"http:\/\/hentati.org\/index.php\/2021\/09\/22\/create-ip-pools-transport-zones\/\">Create IP Pools &amp; Transport Zones<\/a><\/span><\/p>\n<p><span style=\"color: #000000;\">In this article, we will continue with the creation of uplink profile,<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Uplink Profile :<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">An uplink profile defines the policies for the links from hypervisor hosts to the logical switches (segments) or from NSX Edge nodes to top-of-rack switches i.e. teaming policies, active\/standby links, VLAN ID and the MTU setting.<\/span><\/p>\n<p><span style=\"color: #000000;\">There are four pre-defined Uplink Profiles, which satisfies most use cases. This blog focuses on to create a bespoke uplink profile e.g. multi-tep uplink profile which will be utilised later in the series for the compute ESXi hosts.<\/span><\/p>\n<p><span style=\"color: #000000;\">1. Click -&gt; System -&gt;Fabric\u00a0 -&gt; Profiles -&gt; Uplink Profiles -&gt; Add Profile:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-934\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-1.png\" alt=\"\" width=\"1347\" height=\"619\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-1.png 1347w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-1-300x138.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-1-1024x471.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-1-768x353.png 768w\" sizes=\"(max-width: 1347px) 100vw, 1347px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">2. Specify the name, select Teaming Policy as\u00a0<em>Load balance source<\/em>\u00a0and both\u00a0<em>uplink-1,uplink-2<\/em>\u00a0as \u201cActive Uplinks\u201d:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-935\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-2.png\" alt=\"\" width=\"855\" height=\"557\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-2.png 855w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-2-300x195.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-2-768x500.png 768w\" sizes=\"(max-width: 855px) 100vw, 855px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-936\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-3.png\" alt=\"\" width=\"855\" height=\"501\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-3.png 855w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-3-300x176.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-3-768x450.png 768w\" sizes=\"(max-width: 855px) 100vw, 855px\" \/><\/span><\/p>\n<div class=\"elementor-element elementor-element-3d2f002 elementor-widget elementor-widget-text-editor\" data-id=\"3d2f002\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-text-editor elementor-clearfix\">\n<p><span style=\"color: #000000;\">The screenshot below shows the new uplink policy created successfully:<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-937\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-4.png\" alt=\"\" width=\"1345\" height=\"604\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-4.png 1345w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-4-300x135.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-4-1024x460.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-4-768x345.png 768w\" sizes=\"(max-width: 1345px) 100vw, 1345px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Transport Node Profile :<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Transport node profile clubs an IP Pool, Transport Zone(s) and Uplink profile (discussed and created in the previous steps) in a single configuration profile that is applied to the Transport nodes e.g. hypervisors. It defines the network configuration of a transport node with N-VDS configuration, IP assignment and uplink to physical NIC mapping.<\/span><\/p>\n<div class=\"elementor-element elementor-element-da87aea elementor-widget elementor-widget-text-editor\" data-id=\"da87aea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-text-editor elementor-clearfix\">\n<p><span style=\"color: #000000;\">3. Click -&gt; System -&gt;Fabric -&gt; Profiles -&gt; Transport Node Profiles:<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-938\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-5.png\" alt=\"\" width=\"1344\" height=\"616\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-5.png 1344w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-5-300x138.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-5-1024x469.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-5-768x352.png 768w\" sizes=\"(max-width: 1344px) 100vw, 1344px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">4. Specify the Name, select the \u201cOverlay\u201d Transport Zone created previously, Click N-VDS as shown in the screenshot below:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-939\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-6.png\" alt=\"\" width=\"624\" height=\"519\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-6.png 624w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-6-300x250.png 300w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">5. Select the N-VDS, the default NIOC Profile, Uplink profile created, LLDP Profile, IP Assignment , IP Pool also created , Select vmnic2 and vmnic3 (the physical NIC not in used), Click Add PNIC as shown in the screenshot below:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-940\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-7.png\" alt=\"\" width=\"622\" height=\"544\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-7.png 622w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-7-300x262.png 300w\" sizes=\"(max-width: 622px) 100vw, 622px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">This concludes this step of creating a new Transport Node Profile successfully.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-941\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-8.png\" alt=\"\" width=\"1345\" height=\"613\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-8.png 1345w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-8-300x137.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-8-1024x467.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-8-768x350.png 768w\" sizes=\"(max-width: 1345px) 100vw, 1345px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">When a hypervisor host is prepared to function with NSX-T Data Center, the host is known as \u201cFabric Node\u201d which carries the overlay traffic. All fabric nodes have NSX-T Data Center modules installed and are registered with the NSX-T Data Center management plane.<\/span><\/p>\n<p><span style=\"color: #000000;\">For a hypervisor host or a bare metal server to be part of the NSX-T Data Center overlay, it must first be added to the NSX-T Data Center fabric.<\/span><\/p>\n<p><span style=\"color: #000000;\">6. System -&gt; Fabric -&gt; Nodes -&gt; Host Transport Nodes -&gt; Select the Site A\u2019s vCenter Server, as shown in the screenshot below<\/span><\/p>\n<div class=\"elementor-element elementor-element-74effe6 elementor-widget elementor-widget-text-editor\" data-id=\"74effe6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-text-editor elementor-clearfix\">\n<p><span style=\"color: #000000;\">7. Select the compute cluster and click \u201cConfigure NSX\u201d:<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-942\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-9.png\" alt=\"\" width=\"1344\" height=\"615\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-9.png 1344w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-9-300x137.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-9-1024x469.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-9-768x351.png 768w\" sizes=\"(max-width: 1344px) 100vw, 1344px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">8. Select <em>Transport-node-A<\/em> as Deployment Profile -&gt; Click Save as shown in the screenshot below:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-943\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-10.png\" alt=\"\" width=\"604\" height=\"322\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-10.png 604w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-10-300x160.png 300w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><\/span><\/p>\n<div class=\"elementor-element elementor-element-39b4667 elementor-widget elementor-widget-text-editor\" data-id=\"39b4667\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-text-editor elementor-clearfix\">\n<p><span style=\"color: #000000;\">9. Give it a few minutes, and the <em>Configuration State<\/em>\u00a0and\u00a0<em>Node Status<\/em>\u00a0will show\u00a0<em>Success<\/em>\u00a0and\u00a0<em>Up<\/em>:<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-944\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-11.png\" alt=\"\" width=\"1345\" height=\"611\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-11.png 1345w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-11-300x136.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-11-1024x465.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-11-768x349.png 768w\" sizes=\"(max-width: 1345px) 100vw, 1345px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">To verify configuration, we can check on overview:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-945\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-12.png\" alt=\"\" width=\"1351\" height=\"605\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-12.png 1351w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-12-300x134.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-12-1024x459.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-12-768x344.png 768w\" sizes=\"(max-width: 1351px) 100vw, 1351px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">Also by Physical Adapters<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-946\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-13.png\" alt=\"\" width=\"1360\" height=\"618\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-13.png 1360w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-13-300x136.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-13-1024x465.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-13-768x349.png 768w\" sizes=\"(max-width: 1360px) 100vw, 1360px\" \/><\/span><\/p>\n<p><span style=\"color: #000000;\">To visualize the N-VDS from vCenter Server \u2013 Logon to the vCenter -&gt; Click \u201cHosts and Clusters\u201d -&gt; Select Host -&gt; Click Configure -&gt; Expand Networking -&gt; Click Virtual switches:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-947\" src=\"http:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-14.png\" alt=\"\" width=\"1345\" height=\"463\" srcset=\"https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-14.png 1345w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-14-300x103.png 300w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-14-1024x352.png 1024w, https:\/\/hentati.org\/wp-content\/uploads\/2021\/12\/4-14-768x264.png 768w\" sizes=\"(max-width: 1345px) 100vw, 1345px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\">The TEP IPs can also be identified by logging on to the esxi host and running the command below:<\/span><\/p>\n<p><span style=\"color: #000000;\"><em>esxcli network ip interface ipv4 get<\/em><\/span><\/p>\n<p><span style=\"color: #000000;\">Run the following command to perform a ping test using the TEP interface:<\/span><\/p>\n<p><span style=\"color: #000000;\"><em>vmkping ++netstack=vxlan 172.16.100.X<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\"><strong>Note<\/strong>: Even though the overlay encapsulation used in NSX-T is GENEVE, the esxi command is still the same using the stack vxlan.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\">This concludes this step of configuring Host Transport Node successfully.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>(Next Step) Step 5 : <\/strong><a href=\"http:\/\/hentati.org\/index.php\/2021\/10\/04\/configure-edge-transport-node-deploy-nsx-t-edge-vm-create-nsx-edge-cluster\/\">Configure Edge Transport Node, Deploy NSX-T Edge VM &amp; Create NSX Edge Cluster<\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Link for all Steps : 10 Steps to Deploy NSX-T (Previous Step) Step 3 : Create IP Pools &amp; Transport Zones In this article, we will continue with the creation &#8230;<\/p>\n","protected":false},"author":1,"featured_media":1147,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[10],"tags":[],"_links":{"self":[{"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/posts\/933"}],"collection":[{"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/comments?post=933"}],"version-history":[{"count":6,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/posts\/933\/revisions"}],"predecessor-version":[{"id":1112,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/posts\/933\/revisions\/1112"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/media\/1147"}],"wp:attachment":[{"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/media?parent=933"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/categories?post=933"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hentati.org\/index.php\/wp-json\/wp\/v2\/tags?post=933"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}